Dual display pressure sensor

Model: WCPS300 series
  • Product Introduction:
The WCPS300 series high-precision dual display air pressure switch/sensor has a range of 0~-101 kPa/-100~100kPa to choose from. It uses an LCD dual color display screen and has the characteristics of low power consumption, fast response speed, and short circuit protection. It is widely used to replace traditional mechanical air pressure, leak testing, equipment reference pressure confirmation, pipeline pressure detection, and other fields.
 
  • Technical Specifications
Category
Standard form
Multi-functional
Model NPN output PS-301 PS-302 PS-301-M PS-302-M
PNP output PS-301P PS-302P No switch output
Compliant standards and certifications CE Mark (EMC Directive, RoHS Directive)
Types of stress gauge pressure
Rated pressure range -100.0~ +100.0kPa -0.100~ +1.000MPa -100.0~+100.0kPa -0.100~ +1.000MPa
Set pressure range
-100.0~ +100.0kPa
-0.100~ +1.000MPa -100.0~ +100.0kPa -0.100~ +1.000MPa
Pressure resistance test pressure 500kPa 1.5MPa 500kPa 1.5MPa
Power on status, conduct a 30 minute pressure test
Applicable fluids Non corrosive, non flammable, and non explosive gases (when detecting corrosive gases, special models are required and the gas type must be specified)
Power supply voltage 12 to 30V DC ± 10% pulsation P-P10% or less (with reverse protection)
Power consumption Normally: below 240mW (consumes current below 10mA when the power supply voltage is 24V)
ECO mode: below 144mW during STD (consumes current below 6mA when power supply voltage is 24V)
Below 96mW at FULL (current consumption below 4mA when power supply voltage is 24V)
Output method NPN output type RS485 output
NPN open collector transistor Communication protocol: Modbus RTU
Maximum incoming current: 100mA Communication baud rate:
External voltage: below 30V DC (between output terminal and 0) 0000:2400;
Remaining voltage: below 2V (when the incoming current is 100mA) 0001:4800;
PNP output type 0002:9600;
PNP output type 0004:19200;
Maximum current outflow: 100mA 0005:38400;
External voltage: below 30V DC (between output terminal and+V)
The default value is 0002:9600. After successfully changing the communication baud rate, send a response command at the original baud rate and immediately change the device communication baud rate.
Remaining voltage: below 2V (when the source current is 100mA)
Output action Select N.O./N.C. through button operation Output action, read through communication
Output mode EASY mode/Response mode/Window comparison mode
Ying Cha Minimum 1 digit (adjustable)
Repeatability accuracy ±0.1%F.S. ±0.2%F.S. ±0.1%F.S. ±0.2%F.S.
  (±2digits within) (±2digits within) (±2digits within) (±2digits within)
Reaction time 2.5ms、5ms、10ms、25ms、50ms、100ms、250ms、500ms、1,000ms、5,000ms 通过按键操作选择
Short circuit protection Equip
Display color 4-digit+4-digit dual color LCD display
Display cycle (Display refresh cycle: 250ms, 500ms, 1000ms can be selected through button operation)
Display pressure range -100.0~+100.0kPa -0.100~+1.000MPa -100.0~+100.0kPa -0.100~+1.000MPa
Indicator light Red LED Red LED
Output 1 action display light: It lights up when output 1 is turned on;Output 2 analog voltage/current output actionDisplay light: lights up when comparing output 2 ON
When communication is normal, OUT1 and OUT2 flash alternately;
Environmental performance Protect the structure IP40(IEC)
ambient temperature -10 to+50 ℃ (note not to condense or freeze), during storage: -10 to+60 ℃
ambient humidity 35 to 85% RH, during storage: 35 to 85% RH
Withstand Voltage AC1000V 1 minute between all power connection terminals and the casing
insulation resistance Between all power connection terminals and the casing, with a resistance of 50M Ω or higher, based on a DC500V high impedance meter
vibration-resistant Frequency 10 to 500Hz, double amplitude 3mm or maximum acceleration 196m/s, 2 hours in X, Y, and Z directions each
impact resistance Acceleration 100m/s 2 (approximately 10G) 3 times in XYZ directions